Summit Generic Cable Insertion Interface Format
field start length format type 0 1 a s=spot,p=program,e=element,b=break def,r=remark
chnl 1-4 4 nnnn 1-9999
date 5-12 8 yyyymmdd
start 13-18 6 hhmmss
win beg 19-24 6 hhmmss
win dur 25-30 6 hhmmss
length 31-36 6 hhmmss
act tim 37-42 6 hhmmss
skd/flr 43 s/f scheduled spot or filler
id 44-59 16 a user defined - lj, blank filled
remark 60-75 16 a user defined - lj, blank filled
contr 76-80 5 nnnnn traffic def s/n
contr-l 81-85 5 nnnnn traffic def s/n
spot# 86-90 5 nnnnn traffic def s/n
descr 91-120 30 a user defined - lj, blank filled
descr2 121-150 30 a user defined - lj, blank filled
err-ret 151-153 3 nnn error returned from automation
mapped to summit fields: name prog/brk/elem spots type "p","e","b" "s"
chnl
date
start
win beg
win dur
length
act tim
skd/flr
id tape # tape #/spot id
remark remark source
contr prog # contr #
contr-l prog page contr pg
spot# "00000" spot #
descr descr descr
descr2 episode agcy descr
err-ret missed spot description
* user defined = user may enter anything they want including
embedded codes specific to their automation system;